Sign In | Join Free | My ledscreensign.com
China Guangzhou Rongtao Medical Tech LTD. logo
Guangzhou Rongtao Medical Tech LTD.
To be the top preferred ultrasound service company worldwide!
Verified Supplier

5 Years

Home > Ultrasound Machine Repair >

Siemens X150 Ultrasound Machine Repair Laparoscopy Instruments

Guangzhou Rongtao Medical Tech LTD.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Siemens X150 Ultrasound Machine Repair Laparoscopy Instruments

Brand Name : Siemens

Model Number : Siemens X150

Price : Negotiable

Payment Terms : T/T,Western Union

Delivery Time : 2-4 work days

Packaging Details : Neutral Package

Category : laparoscopy instruments

Description : certified refurbished echo ultrasound

System : troubleshooting ultrasound device

Warranty : 60 days after fixed

Condition : Siemens X150 used medical device

Purpose : medical repair engineer team

Contact Now

Simens X150 Medical Equipment Assemble Repair

Simens X150 System Reports Error

Siemens ventilator has internal alarm system test function, technical error should be the test alarm system failure prompt. There are three reasons for this failure:

The first is the failure of the system software;

The second is the device behind the speaker failure;

The third is the PC1777 circuit board hardware failure.

After the boot into the maintenance engineer software status, the use of software is proofread, found that the latest version of the system software is running normally, and then the loudspeaker test, show that its working parameters are not normal.

Apart the speaker will be removed after breathing machine screen, measured with a multimeter and found that the parts have been damaged, intends to replace the original speaker, but the factory price is very expensive, according to the measured parameters, found that a speaker can completely replace the electronics market performance, be replaced after purchase, installed the screen restart, not the technical errors now red alarm, The fault is removed.




Ultrasound parts that we can repair:

Repair List of Featured Ultrasonic Board & Assy
Brand System Description Part Number
GE Logiq P5 CPU mainboard 5168431
GE Logiq P6 CPU mainboard
GE Logiq E9/vivid E9 GFI2 5161631
GE Voluson E6/Voluson E8 RSR KTI301394-2/KTI196357
GE Voluson E6/Voluson E8 RFI/ RFI21b Board KTI300614/KTI302197-6
GE Voluson S6/S8/P8 BF64 5396937-2
GE Voluson S6/S8/P8 RFS board 5364098-2/5364098-3
GE Voluson S6/S10/P8 BF192 board 5357234
Aloka Alpha 5 mainboard EP493700DD
Aloka Alpha 6 RX Beam Former EP555501AA
Aloka Alpha 6 CW board EP555700
Aloka Alpha 6 CPU mainboard EP537000/EP563000
Aloka Alpha 6 TX/RX EP555300
Aloka Alpha 6/Alpha 7 DOM EP550000AA
Aloka Alpha 10 RX Beamformer board EP531800CE
Aloka Alpha 10 wave generator Board EP495000HH/EP495000HJ/EP495000FF
Hitachi F37 TX/RS EP557400/EP557300
Hitachi F37 mainboard EP575700BC/EP560800
Aloka F75 USP board EP556600
Aloka F75 Cell Board EP558800
Hitachi HI VISION Avius RDBF board 7513907A/7513612
Hitachi Arietta 60 CELL EU-9160C
Hitachi Arietta 70 TX EP572300AA
Hitachi Arietta 70 CELL
Hitachi Noblus CELL
Hitachi Noblus CONT-B
Hitachi Ascendus CELL 7352830A
Siemens X150/G40 BE 10131804
Siemens X300 BE 2.0/BE 3.0/BE 7.5 10131990
Siemens X700 BE 10136465
Siemens X700 RC 10136467
Siemens X700 TI 11014292
Siemens Antares BE 7472421
Siemens Antares CB 7288504
Siemens S2000 RM300 10852163
Siemens S2000 high version/S3000 RM301 10854749
iU22/iE33 EMB excelsior motherboard 453561419431/453561382231/453561419431
iU22/iE33 UMB Unified Motherboard 453561254492/453561360251
HD15 ACB acquisition control board 453561197145/453561197144
HD15 AIM board 4.53561E+11
CX50 control panel 4.53562E+11
CX50 mainboard 453561368033/453561622163/453561495832
Affiniti 70 ACQ acquisition control board
EPIQ 5/EPIQ 7 ACQ Acquisition Module board 453561734844/453561704246
Biosound Mylab Series CPU mainboard 9501361000
Toshiba Aplio 300/400/500 mainboard PM30-38696
Toshiba Aplio 500 RX ywm2056*a
Toshiba Xario 200 TX PM30-32732-1
Toshiba Xario 200 RX PM30-32733-1
Remarks
1.The repair cycle is within 3-5 days.
2.Warranty after fixed:60 days.
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge.
4.Package price is available if repair 3 pcs or more at one time.
5.Extra discount for VIP partners.
6.You could have different part No.under same description.



Product Tags:

Simens X150 Ultrasound Machine Repair

      

Laparoscopy Ultrasound Machine Repair

      
Quality Siemens X150 Ultrasound Machine Repair Laparoscopy Instruments for sale

Siemens X150 Ultrasound Machine Repair Laparoscopy Instruments Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Rongtao Medical Tech LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)